          Your position:Home > Products > Heat Source

          Heat Carrier Boiler

          Thermal efficiency: ≤90%

          Applications: it is applied to production industries such as metallurgy, drying, chemistry, building materials, refractory materials and fertilizer.  

          Materials: fuel oil
          Product introduction: YYW series organic heat carrier boiler is also called fast loading and forced circulation fuel (gas). This series of boiler is characterized by large heating area and compact area. Heating area consists of coil pipes which are placed closely at inside, middle and o ut side (or inside and outside). 

          Sales Hotline:

          0086-18539990967

          Technical introduction

          Advantages

          Working principle

          YYW series organic heat carrier boiler is also called fast loading and forced circulation fuel (gas). This series of boiler is characterized by large heating area and compact area. Heating area consists of coil pipes which are placed closely at inside, middle and o ut side (or inside and outside). Inner coil pipes are radiation heating surface.
          There is a convection heating surface formed between middle&outer coil pipes and inner coil pipes. Fuels are burnt and release heat in combustion chamber which is composed of inner coil pipes. After most amount of heat is absorbed by radiation heating-surface, flue gas with high temperature will enter convection heating surface for heat exchange. Efficient four-return design achieves even heat and low thermal inertia. Air enters boiler from air inlet of burner at the front of boiler. Then, air will pass through jacket between inner and outer layer from all around and join combustion at the back part. In this process, flue gas forms four returns and is discharged out from chimney. 
          Oil fired organic heat carrier boiler

          Technical parameters

          Technical parameters of organic heat carrier boiler:
          Model
           Name
          YYW0.3
          (25)
          YYW0.35
          (30)
          YYW0.6
          (50)
          YYW0.9
          (75)
          YYW1.2
          (100)
          YYW1.5
          (235)
          YYW1.8
          (150)
          YYW2.5
          (200)
          YYW3
          (250)
          KW
          Rated power
          0.3 0.35 0.6 0.9 1.2 1.5 1.8 2.5 3
          %
          Thermal efficiency
          90 90 90 90 90 90 90 90 90
          Mpa
          Designed pressure
          1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
          °C
          Maximum temperature
          350 350 350 350 350 350 350 350 350

          Oil capacity in boiler
          0.21 0.25 0.28 0.44 0.64 0.793 1.25 1.76 1.90
          m³/h
          Circular oil amount
          40 40 80 80 80 100 100 200 200
          DN
          Connecting piping diameter
          100 100 100 100 125 125 125 150 150
          KW
          System installed capacity
          14 14 22 22 40 40 40 66 70
          Dimension Diameter 1016 1016 1216 1416 1716 1716 2000 2000 2320
          Height 2050 2350 2450 2900 3300 3900 4100 5100 5300
           
          Model
           
           Name
          YLW-1200 YLW-1400 YLW-1750 YLW-2350 YLW-2900 YLW-3500
          KW
          Rated thermal power
          1.25 1.4 1.78 2.5 3.0 3.5
          %
          Thermal efficiency
          78 78 78 78 78 78
          Mpa
          Designed pressure
          1.0 1.0 1.0 1.0 1.0 1.0
          °C
          Maximum
          350 350 350 350 350 350
          1.1 1.2 1.8 2.6 3.3 3.8
          m³/h
          Circulating oil am
          110 130 160 180 220 240
          DN
          Connecting piping diameter
          125 125 150 150 200 200
          KW
          System installed capacity
          40 40 40 56 66 100
          m
          Dimension
          Height 6 6 6 6 6.2 6.2
          Width 2.2 2.6 2.6 2.8 3 3
          Height 4 4.5 4.8 5.5 6 6
           
           

          Relevant products

          Relevant cases

          Order Online

          Please pay attention: in order to get timely contact with you, please leave us your complete information such as your contact number, your demand (types of your raw materials, volume, feed size and size of final products); you can also contact us by business link. Really hope we can be your stasified partner.

          • Product:
          • Name:
          • Email:
          • Usage Region:
          • Your Demand:

          Sludge Reclamation

          Matching Device

          Sales hotline:0086-18539990967

          Address of headquarters:NO. 198, longding industrial zone, high-tech development zone, zhengzhou city, china

          Email:vip@tdaxy.com

          Zhengzhou Taida Group    Address:NO. 198,longding industrial zone,high-tech development zone,zhengzhou city,china    Sitemap

          真人做人爱试看一

          <tr id="kt2mz"></tr>
          1. <object id="kt2mz"></object>
            <big id="kt2mz"></big>
          2. <object id="kt2mz"><option id="kt2mz"><mark id="kt2mz"></mark></option></object>
              1. <object id="kt2mz"></object>
                <center id="kt2mz"><em id="kt2mz"><p id="kt2mz"></p></em></center>
              2. <code id="kt2mz"><sup id="kt2mz"><track id="kt2mz"></track></sup></code>